This website is intended for healthcare professionals only

Trending Topic

31 mins

Trending Topic

Developed by Touch
Mark CompleteCompleted
BookmarkBookmarked

Ventricular fibrillation (VF) is characterized by rapid (>300 beats a per minute), irregular electrical activation with variable electrocardiographic waveforms that prevents coordinated myocardial contraction, resulting in immediate loss of cardiac output.1 It most commonly occurs in the context of coronary artery disease.2,3 Resuscitation efforts are critically time-dependent: with each minute of untreated VF, the survival rate declines […]

105/Emergency out-of-hours complex cardiovascular implantable electronic devices

N Papageorgiou (Presenting Author) - Barts Heart Centre, London; A Tyrlis - Barts Heart Centre, London; A Chow - Barts Heart Centre, London; M Lowe - Barts Heart Centre, London; C Monkhouse - Barts Heart Centre, London; A Muthumala - Barts Heart Centre, London; A Creta - Barts Heart Centre, London; M Dhinoja - Barts Heart Centre, London; RJ Hunter - Barts Heart Centre, London; S Sporton - Barts Heart Centre, London; MJ Earley - Barts Heart Centre, London; RJ Schilling - Barts Heart Centre, London; M Finlay - Barts Heart Centre, London
2 mins
Share
Facebook
X (formerly Twitter)
LinkedIn
Via Email
Mark CompleteCompleted
BookmarkBookmarked
Copy LinkLink Copied
Published Online: Sep 27th 2010 European Journal of Arrhythmia & Electrophysiology. 2020;6(Suppl. 1):abstr105
Select a Section…
1

Article

Introduction: Emergency out-of-hours destination cardiovascular implantable device (CIDs) insertion has become established as preferable to temporary pacing waiting in anticipation of a working hours procedure slot. A frequent conundrum is the patient who may benefit from a more complex CID such as implantable cardioverter defibrillators (ICD) or cardiac resynchronization therapy (CRT), but who requires immediate pacing. Barts Heart Centre offers out-of-hours emergency complex device insertion where clinically indicated. We aimed to assess the safety of this approach.

Methods: A retrospective analysis of all out-of-hours complex CIDs was performed between June 2015 and May 2019 was performed. An “out-of-hours” case was considered to be a case where start time was after 1700 or before 0800 on weekdays, at weekends or on UK Bank Holidays, and which had been classed as an “emergency” implant. We excluded planned inter-hospital transfers, who were overwhelmingly stable patients, and any out-of-hours elective work.

Results: We identified 766 out-of-hours devices. Of those and after excluding pacemakers, 59 cases fulfilled the inclusion criteria; 24 ICD, 19 CRT-D and 16 CRT-P. Four displaced leads (1 ICD right ventricular lead and 3 CRT-D left ventricular leads) were identified on post-implant check. There were no other procedural complications. In addition, the skin-skin mean procedure time was 93 ± 44 minutes, with 10 ± 9.3 minutes mean fluoroscopy time (Table). Of note, complications, procedure and radiation times were comparable to previously published ranges.

Conclusions: Our experience demonstrates that implantation of emergency out-of-hours complex devices is safe and does not expose patients to higher radiation or procedure times.

 

2

Further Resources

Share
Facebook
X (formerly Twitter)
LinkedIn
Via Email
Mark CompleteCompleted
BookmarkBookmarked
Copy LinkLink Copied
Close Popup